ROHS Substances table<br />

51<br />

ROHS Name<br />

CAS<br />

TWAEV<br />

STEV<br />

Ceil<strong>in</strong>g<br />

(mg/m³)<br />

Notes<br />

<strong>Sampl<strong>in</strong>g</strong><br />

Device<br />

Flow<br />

L/m<strong>in</strong><br />

Volume<br />

TWAEV<br />

STEV<br />

(L)<br />

Pr<strong>in</strong>ciple<br />

MRV<br />

µg<br />

CVa<br />

(%)<br />

#<br />

meth.<br />

Remarks<br />

Beryllium [7440-41-7],<br />

metal and compounds<br />

(as Be)<br />

7440-41-7<br />

0,00015 C1<br />

RP<br />

EM<br />

S<br />

Mixed cellulose ester filter 0.8 µm, 37mm<br />

or 25 mm, closed cassette<br />

905 MCE filter-37<br />

915 MCE filter-25<br />

1,5 ICP-MS 0,0005 3,59<br />

180 IRSST<br />

359<br />

Cassettes 913 or 916, whose filters are preweighed, can also be used. For<br />

surface wipe sampl<strong>in</strong>g, contact Laboratory Customer Service.<br />

Specific sampl<strong>in</strong>g must be carried out <strong>for</strong> this substance. The analytical results<br />

are expressed as total beryllium.<br />

Biphenyl<br />

92-52-4<br />

1,3 XAD-7 tube 100/50 mg<br />

0,2 20 GC-FID<br />

OSHA<br />

PV2022<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Bismuth telluride (as<br />

Bi2Te3), Se-doped<br />

1304-82-1<br />

5 SKC 225-8-01-1 or 225-8-04 polyv<strong>in</strong>yl 1,5 180 Grav 25 4,9 IRSST<br />

48-1<br />

chloride filter<br />

902 PVC filter-37<br />

914 PVC filter-25<br />

Additional <strong>in</strong><strong>for</strong>mation is available <strong>in</strong> Info-Labo 91-03. The weight measurement<br />

method <strong>for</strong> dusts is by def<strong>in</strong>ition non-specific.<br />

Bismuth telluride (as<br />

Bi2Te3), Se-doped<br />

1304-82-1<br />

5 Mixed cellulose ester filter<br />

2 960 FAAS<br />

OSHA<br />

ID121<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

A stoichiometric factor must be applied.<br />

Bismuth telluride (as<br />

Bi2Te3), Undoped<br />

1304-82-1<br />

10 SKC 225-8-01-1 or 225-8-04 polyv<strong>in</strong>yl 1,5 180 Grav 25 4,9 IRSST<br />

48-1<br />

chloride filter<br />

902 PVC filter-37<br />

914 PVC filter-25<br />

Additional <strong>in</strong><strong>for</strong>mation is available <strong>in</strong> Info-Labo 91-03. The weight measurement<br />

method <strong>for</strong> dusts is by def<strong>in</strong>ition non-specific.<br />

Bismuth telluride (as<br />

Bi2Te3), Undoped<br />

1304-82-1<br />

10 Mixed cellulose ester filter<br />

2 960 FAAS<br />

OSHA<br />

ID121<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

A stoichiometric factor must be applied.<br />

Boron oxide<br />

1303-86-2<br />

10 SKC 225-8-01-1 or 225-8-04 polyv<strong>in</strong>yl 1,5 180 Grav 25 4,9 IRSST<br />

48-1<br />

chloride filter<br />

902 PVC filter-37<br />

914 PVC filter-25<br />

Additional <strong>in</strong><strong>for</strong>mation is available <strong>in</strong> Info-Labo 91-03. The weight measurement<br />

method <strong>for</strong> dusts is by def<strong>in</strong>ition non-specific.<br />

Boron tribromide<br />

10294-33-4<br />

--<br />

--<br />

10<br />

RP Prefilter PTFE with silver membrane<br />

0,3-1 360 IC-CD<br />

NIOSH<br />

6011<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

The bromide and bromate ions are analyzed.