ROHS Substances table<br />
60<br />
ROHS Name<br />
CAS<br />
TWAEV<br />
STEV<br />
Ceil<strong>in</strong>g<br />
(mg/m³)<br />
Notes<br />
<strong>Sampl<strong>in</strong>g</strong><br />
Device<br />
Flow<br />
L/m<strong>in</strong><br />
Volume<br />
TWAEV<br />
STEV<br />
(L)<br />
Pr<strong>in</strong>ciple<br />
MRV<br />
µg<br />
CVa<br />
(%)<br />
#<br />
meth.<br />
Remarks<br />
bis (Chloromethyl) e<strong>the</strong>r<br />
542-88-1<br />
0,0047 C1<br />
RP<br />
EM<br />
Two glass fritted imp<strong>in</strong>gers conta<strong>in</strong><strong>in</strong>g a<br />
solution of methanol and 2,4,6-<br />
trichlorophenol.<br />
0,5 50 GC-ECD<br />
OSHA<br />
10<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
1-Chloro-1-nitropropane<br />
600-25-9<br />
10 Chromosorb-108 tube<br />
0,2 12 GC-FID<br />
NIOSH<br />
S211<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Chloropentafluoroethane<br />
76-15-3<br />
6320 Activated charcoal tube 100/50 mg<br />
0,05 2,5 GC-FID<br />
OSHA<br />
IMISC135<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Chloropicr<strong>in</strong><br />
76-06-2<br />
0,67 Two XAD-4 80/40 mg tubes <strong>in</strong> series<br />
0,2 5 GC-ECD<br />
OSHA<br />
PV2103<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
ß-Chloroprene<br />
126-99-8<br />
36 Pc Activated charcoal tube 100/50 mg<br />
0,01- 8 GC-FID<br />
NIOSH<br />
1002<br />
0,1<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
3-Chloropropene<br />
107-05-1<br />
3<br />
6<br />
Activated charcoal tube 100/50 mg<br />
0,01-1 100 GC-FID<br />
15<br />
NIOSH<br />
1000<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
2-chloropropionic acid<br />
598-78-7<br />
0,44 Pc Silica gel tube 100/50 mg<br />
0,05- 100 IC-CD<br />
NIOSH<br />
2008<br />
0,2<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Stable <strong>for</strong> at least 7 days at 25°C and 32 days at 4°C<br />
o-Chlorostyrene<br />
2039-87-4<br />
283<br />
425<br />
Activated charcoal tube 100/50 mg<br />
0,01-<br />
0,2<br />
20<br />
3<br />
GC-FID<br />
NIOSH<br />
1003<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
NIOSH method 1003 is <strong>for</strong> halogenated hydrocarbons, which does not<br />
specifically <strong>in</strong>clude o-chlorostyrene.<br />
o-Chlorotoluene<br />
95-49-8<br />
259 Activated charcoal tube 100/50 mg<br />
0,01- 10<br />
0,2 3<br />
GC-FID<br />
NIOSH<br />
1003<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
NIOSH method 1003 is <strong>for</strong> halogenated hydrocarbons, which does not<br />
specifically <strong>in</strong>clude o-chlorotoluene.<br />
Chlorpyrifos<br />
2921-88-2<br />
0,2 Pc OVS tube with XAD-2 and glass fiber filter 0,2-1 240 GC-FPD<br />
NIOSH<br />
5600<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Some phosphates may cause <strong>in</strong>terference dur<strong>in</strong>g <strong>the</strong> analysis.