ROHS Substances table<br />

61<br />

ROHS Name<br />

CAS<br />

TWAEV<br />

STEV<br />

Ceil<strong>in</strong>g<br />

(mg/m³)<br />

Notes<br />

<strong>Sampl<strong>in</strong>g</strong><br />

Device<br />

Flow<br />

L/m<strong>in</strong><br />

Volume<br />

TWAEV<br />

STEV<br />

(L)<br />

Pr<strong>in</strong>ciple<br />

MRV<br />

µg<br />

CVa<br />

(%)<br />

#<br />

meth.<br />

Remarks<br />

Chromium (metal)<br />

Chromium (III)<br />

compounds (as Cr)<br />

7440-47-3<br />

0,5 Mixed cellulose ester filter, 0.8µm, 25 and 1,5 180 ICP-MS 1 3,75 IRSST<br />

362<br />

37 mm.<br />

905 MCE filter-37<br />

915 MCE filter-25<br />

0,5 Mixed cellulose ester filter, 0.8µm, 25 and 1,5 180 ICP-MS 1 3,75 IRSST<br />

362<br />

37 mm.<br />

905 MCE filter-37<br />

915 MCE filter-25<br />

Cassettes 913 or 916, whose filters are preweighed, can also be used. For<br />

surface wipe sampl<strong>in</strong>g, contact Laboratory Customer Service.<br />

The analytical results are expressed as total chromium.<br />

Cassettes 913 or 916, whose filters are preweighed, can also be used. For<br />

surface wipe sampl<strong>in</strong>g, contact Laboratory Customer Service.<br />

The analytical results are expressed as total chromium.<br />

Chromium VI, water<br />

<strong>in</strong>soluble <strong>in</strong>organic<br />

compounds (as Cr)<br />

0,01 C1<br />

RP<br />

EM<br />

S<br />

PALL CA28149-306 v<strong>in</strong>yl/acrylic<br />

copolymer filter<br />

926 V<strong>in</strong>yl/acrylic copolymer filter<br />

1,5 à 4 360 IC-VIS 0,04 4,4 IRSST<br />

365<br />

For surface wipe sampl<strong>in</strong>g, contact Laboratory Customer Service.<br />

The analytical results are expressed as total water-<strong>in</strong>soluble chromium VI.<br />

Surface tests <strong>for</strong> chromates can be carried out, and <strong>the</strong> required equipment (kit<br />

#2625) is available at <strong>the</strong> IRSST. See communiqué 2008-06 on our Web site.<br />

Analysis time of 8 days <strong>for</strong> weld<strong>in</strong>g fumes and 10 days <strong>for</strong> <strong>the</strong> o<strong>the</strong>r processes<br />

follow<strong>in</strong>g <strong>the</strong> sampl<strong>in</strong>g date. Ship all samples by rapid courier with<strong>in</strong> a period not<br />

exceed<strong>in</strong>g 24 hours after sampl<strong>in</strong>g.<br />

Any substance that produces a response on <strong>the</strong> detector at 540 nm and that has<br />

a retention time similar to Cr VI is a potential <strong>in</strong>terference.<br />

Chromium VI, water<br />

soluble <strong>in</strong>organic<br />

compounds (as Cr)<br />

0,05 C1<br />

RP<br />

EM<br />

S<br />

PALL CA28149-306 v<strong>in</strong>yl/acrylic<br />

copolymer filter<br />

926 V<strong>in</strong>yl/acrylic copolymer filter<br />

1,5 à 4 360 IC-VIS 0,04 2,29 IRSST<br />

365<br />

For surface wipe sampl<strong>in</strong>g, refer to Appendix 3 of <strong>the</strong> sampl<strong>in</strong>g guide.<br />

The analytical results are expressed as total water-soluble chromium VI.<br />

Surface tests <strong>for</strong> chromates can be carried out, and <strong>the</strong> required equipment (kit<br />

#2625) is available at <strong>the</strong> IRSST. See communiqué 2008-06 on our Web site.<br />

Analysis time of 8 days <strong>for</strong> weld<strong>in</strong>g fumes and 10 days <strong>for</strong> <strong>the</strong> o<strong>the</strong>r processes<br />

follow<strong>in</strong>g <strong>the</strong> sampl<strong>in</strong>g date. Ship all samples by rapid courier with<strong>in</strong> a period not<br />

exceed<strong>in</strong>g 24 hours after sampl<strong>in</strong>g.<br />

Any substance that produces a response on <strong>the</strong> detector at 540 nm and that has<br />

a retention time similar to Cr VI is a potential <strong>in</strong>terference.<br />

Chromium VI, water<br />

soluble <strong>in</strong>organic<br />

compounds (as Cr)<br />

0,05 C1<br />

RP<br />

EM<br />

S<br />

Not available (refer to commmuniqué<br />

2012-03)<br />

927<br />

IRSST<br />

365<br />

For chromium VI <strong>in</strong> an acid aerosol.<br />

Chromyl chloride<br />

14977-61-8<br />

0,16<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

No support<strong>in</strong>g reference is suggested <strong>for</strong> this product.