Sampling Guide for Air Contaminants in the Workplace - Irsst
Sampling Guide for Air Contaminants in the Workplace - Irsst
Sampling Guide for Air Contaminants in the Workplace - Irsst
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
ROHS Substances table<br />
118<br />
ROHS Name<br />
CAS<br />
TWAEV<br />
STEV<br />
Ceil<strong>in</strong>g<br />
(mg/m³)<br />
Notes<br />
<strong>Sampl<strong>in</strong>g</strong><br />
Device<br />
Flow<br />
L/m<strong>in</strong><br />
Volume<br />
TWAEV<br />
STEV<br />
(L)<br />
Pr<strong>in</strong>ciple<br />
MRV<br />
µg<br />
CVa<br />
(%)<br />
#<br />
meth.<br />
Remarks<br />
Sodium bisulfite<br />
7631-90-5<br />
5 SKC 225-8-01-1 or 225-8-04 polyv<strong>in</strong>yl 1,5 180 Grav 25 4,9 IRSST<br />
48-1<br />
chloride filter<br />
902 PVC filter-37<br />
914 PVC filter-25<br />
Additional <strong>in</strong><strong>for</strong>mation is available <strong>in</strong> Info-Labo 91-03. The weight measurement<br />
method <strong>for</strong> dusts is by def<strong>in</strong>ition non-specific.<br />
Sodium fluoroacetate<br />
62-74-8<br />
0,05<br />
0,15<br />
Pc Mixed cellulose ester filter<br />
1,5-2 480 IC-CD<br />
NIOSH<br />
S301<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Sodium hydroxide<br />
1310-73-2<br />
--<br />
--<br />
2<br />
RP Gelman 66467 polyv<strong>in</strong>yl chloride filter 5 1,5 180 FAAS 5<br />
IRSST<br />
287-1<br />
µm<br />
903 PVC filter-37<br />
Specific sampl<strong>in</strong>g must be carried out <strong>for</strong> this substance. All soluble sodium<br />
salts are positive <strong>in</strong>terferences.<br />
The results are expressed as total soluble sodium. A stoichiometric factor must<br />
be applied.<br />
Sodium metabisulfite<br />
7681-57-4<br />
5<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
IRSST method 287-1 is <strong>for</strong> <strong>the</strong> analysis of total soluble sodium and can be<br />
adapted to this product.<br />
Sodium metabisulfite<br />
7681-57-4<br />
5 SKC 225-8-01-1 or 225-8-04 polyv<strong>in</strong>yl 1,5 180 Grav 25 4,9 IRSST<br />
48-1<br />
chloride filter<br />
902 PVC filter-37<br />
914 PVC filter-25<br />
Additional <strong>in</strong><strong>for</strong>mation is available <strong>in</strong> Info-Labo 91-03. The weight measurement<br />
method <strong>for</strong> dusts is by def<strong>in</strong>ition non-specific.<br />
Borates, tetra, sodium<br />
salt , Anhydrous<br />
1330-43-4<br />
1 Mixed cellulose ester filter<br />
1-4 500 ICP<br />
NIOSH<br />
7300<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
NIOSH method 7300 is used <strong>for</strong> metals and can be adapted to boron.<br />
Borates, tetra, sodium<br />
salt , Decahydrate<br />
1303-96-4<br />
5 Mixed cellulose ester filter<br />
1-4 500 ICP<br />
NIOSH<br />
7300<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
NIOSH method 7300 is used <strong>for</strong> metals and can be adapted to boron.<br />
Borates, tetra, sodium<br />
salt , Pentahydrate<br />
12045-88-4<br />
1 Mixed cellulose ester filter<br />
1-4 500 ICP<br />
NIOSH<br />
7300<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
NIOSH method 7300 is used <strong>for</strong> metals and can be adapted to boron.<br />
Starch<br />
9005-25-8<br />
10 Pt SKC 225-8-01-1 or 225-8-04 polyv<strong>in</strong>yl 1,5 180 Grav 25 4,9 IRSST<br />
48-1<br />
chloride filter<br />
902 PVC filter-37<br />
914 PVC filter-25<br />
Additional <strong>in</strong><strong>for</strong>mation is available <strong>in</strong> Info-Labo 91-03. The weight measurement<br />
method <strong>for</strong> dusts is by def<strong>in</strong>ition non-specific.