ROHS Substances table<br />

118<br />

ROHS Name<br />

CAS<br />

TWAEV<br />

STEV<br />

Ceil<strong>in</strong>g<br />

(mg/m³)<br />

Notes<br />

<strong>Sampl<strong>in</strong>g</strong><br />

Device<br />

Flow<br />

L/m<strong>in</strong><br />

Volume<br />

TWAEV<br />

STEV<br />

(L)<br />

Pr<strong>in</strong>ciple<br />

MRV<br />

µg<br />

CVa<br />

(%)<br />

#<br />

meth.<br />

Remarks<br />

Sodium bisulfite<br />

7631-90-5<br />

5 SKC 225-8-01-1 or 225-8-04 polyv<strong>in</strong>yl 1,5 180 Grav 25 4,9 IRSST<br />

48-1<br />

chloride filter<br />

902 PVC filter-37<br />

914 PVC filter-25<br />

Additional <strong>in</strong><strong>for</strong>mation is available <strong>in</strong> Info-Labo 91-03. The weight measurement<br />

method <strong>for</strong> dusts is by def<strong>in</strong>ition non-specific.<br />

Sodium fluoroacetate<br />

62-74-8<br />

0,05<br />

0,15<br />

Pc Mixed cellulose ester filter<br />

1,5-2 480 IC-CD<br />

NIOSH<br />

S301<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Sodium hydroxide<br />

1310-73-2<br />

--<br />

--<br />

2<br />

RP Gelman 66467 polyv<strong>in</strong>yl chloride filter 5 1,5 180 FAAS 5<br />

IRSST<br />

287-1<br />

µm<br />

903 PVC filter-37<br />

Specific sampl<strong>in</strong>g must be carried out <strong>for</strong> this substance. All soluble sodium<br />

salts are positive <strong>in</strong>terferences.<br />

The results are expressed as total soluble sodium. A stoichiometric factor must<br />

be applied.<br />

Sodium metabisulfite<br />

7681-57-4<br />

5<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

IRSST method 287-1 is <strong>for</strong> <strong>the</strong> analysis of total soluble sodium and can be<br />

adapted to this product.<br />

Sodium metabisulfite<br />

7681-57-4<br />

5 SKC 225-8-01-1 or 225-8-04 polyv<strong>in</strong>yl 1,5 180 Grav 25 4,9 IRSST<br />

48-1<br />

chloride filter<br />

902 PVC filter-37<br />

914 PVC filter-25<br />

Additional <strong>in</strong><strong>for</strong>mation is available <strong>in</strong> Info-Labo 91-03. The weight measurement<br />

method <strong>for</strong> dusts is by def<strong>in</strong>ition non-specific.<br />

Borates, tetra, sodium<br />

salt , Anhydrous<br />

1330-43-4<br />

1 Mixed cellulose ester filter<br />

1-4 500 ICP<br />

NIOSH<br />

7300<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

NIOSH method 7300 is used <strong>for</strong> metals and can be adapted to boron.<br />

Borates, tetra, sodium<br />

salt , Decahydrate<br />

1303-96-4<br />

5 Mixed cellulose ester filter<br />

1-4 500 ICP<br />

NIOSH<br />

7300<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

NIOSH method 7300 is used <strong>for</strong> metals and can be adapted to boron.<br />

Borates, tetra, sodium<br />

salt , Pentahydrate<br />

12045-88-4<br />

1 Mixed cellulose ester filter<br />

1-4 500 ICP<br />

NIOSH<br />

7300<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

NIOSH method 7300 is used <strong>for</strong> metals and can be adapted to boron.<br />

Starch<br />

9005-25-8<br />

10 Pt SKC 225-8-01-1 or 225-8-04 polyv<strong>in</strong>yl 1,5 180 Grav 25 4,9 IRSST<br />

48-1<br />

chloride filter<br />

902 PVC filter-37<br />

914 PVC filter-25<br />

Additional <strong>in</strong><strong>for</strong>mation is available <strong>in</strong> Info-Labo 91-03. The weight measurement<br />

method <strong>for</strong> dusts is by def<strong>in</strong>ition non-specific.