ROHS Substances table<br />

67<br />

ROHS Name<br />

CAS<br />

TWAEV<br />

STEV<br />

Ceil<strong>in</strong>g<br />

(mg/m³)<br />

Notes<br />

<strong>Sampl<strong>in</strong>g</strong><br />

Device<br />

Flow<br />

L/m<strong>in</strong><br />

Volume<br />

TWAEV<br />

STEV<br />

(L)<br />

Pr<strong>in</strong>ciple<br />

MRV<br />

µg<br />

CVa<br />

(%)<br />

#<br />

meth.<br />

Remarks<br />

Diacetone alcohol<br />

123-42-2<br />

238 SKC 226-01 activated charcoal tube<br />

Max: 10 GC-FID 46 4,1 IRSST<br />

133-1<br />

2120 Activated charcoal 100/50 mg<br />

0,2<br />

Diacetone alcohol must be specifically sampled due to a specific desorption<br />

solvent.<br />

1,6-Diam<strong>in</strong>ohexane<br />

124-09-4<br />

2,3 Silica gel tube 150/75 mg<br />

0,01-1 30 GC-NPD<br />

NIOSH<br />

2010<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Diaz<strong>in</strong>on®<br />

333-41-5<br />

0,1 Pc Supelco ORBO 49P tube, # 2-350<br />

0,2-1 480 GC-NPD 2<br />

IRSST<br />

228-1<br />

2180 Orbo 49P<br />

Diaz<strong>in</strong>on must be specifically sampled due to <strong>the</strong> sampl<strong>in</strong>g device used and a<br />

specific desorption solvent.<br />

Diazomethane<br />

334-88-3<br />

0,34 XAD-2 tube impregnated with octanoic 0,2 10 GC-FID<br />

NIOSH<br />

2515<br />

acid.<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Diborane<br />

19287-45-7<br />

0,11 Teflon filter <strong>in</strong> series with a charcoal tube 0,5-1 120 ICP-MS<br />

NIOSH<br />

6006<br />

impregnated with an oxidant.<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

1,2-Dibromoethane<br />

106-93-4<br />

155 Pc<br />

C2<br />

RP<br />

EM<br />

Activated charcoal tube 100/50 mg<br />

0,02-<br />

0,2<br />

25 GC-ECD<br />

NIOSH<br />

1008<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Dibutyl phenyl<br />

phosphate<br />

2528-36-1<br />

3,5 Pc Polytetrafluorocarbon (teflon) filter<br />

1-3 200 GC-FPD<br />

NIOSH<br />

5017<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

NIOSH method 5017 is <strong>for</strong> dibutyl phosphate and can be adapted to this<br />

substance.<br />

Dibutyl phosphate<br />

107-66-4<br />

8,6<br />

17<br />

Polytetrafluorocarbon (teflon) filter<br />

1-3 200 GC-FPD<br />

45<br />

NIOSH<br />

5017<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Dibutyl phthalate<br />

84-74-2<br />

5 Whatman 7188 003 cellulose nitrate filter 1,0 30 HPLC-UV 8<br />

IRSST<br />

308-1<br />

912 CN filter-37<br />

Store <strong>in</strong> refrigerator after sampl<strong>in</strong>g.<br />

2-N-Dibutylam<strong>in</strong>oethanol<br />

102-81-8<br />

14 Pc Silica gel tube 300/150 mg<br />

0,01- 24 GC-FID<br />

NIOSH<br />

2007<br />

0,2<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.