Sampling Guide for Air Contaminants in the Workplace - Irsst
Sampling Guide for Air Contaminants in the Workplace - Irsst
Sampling Guide for Air Contaminants in the Workplace - Irsst
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Substances non regulated from ROHS<br />
Yellow section <strong>in</strong> <strong>the</strong> orig<strong>in</strong>al document<br />
136<br />
Name<br />
CAS<br />
<strong>Sampl<strong>in</strong>g</strong> device<br />
Flow<br />
L/m<strong>in</strong><br />
Volume<br />
Pr<strong>in</strong>ciple<br />
MRV<br />
µg<br />
CVa<br />
%<br />
#<br />
meth.<br />
Remarks<br />
N-Nitrosopipérid<strong>in</strong>e<br />
100-75-4<br />
Florisil tube 500 mg with pre-tube<br />
2210 Florisil tube with pre-tube<br />
1-2 1000 GC-NPD 0,04 4,3<br />
IRSST<br />
371<br />
The recommended sampl<strong>in</strong>g volume is 400 to 1000 litres. The samples can be<br />
kept <strong>for</strong> 4 weeks <strong>in</strong> <strong>the</strong> dark at 4°C.The simulltaneous determ<strong>in</strong>ation of 8<br />
nitrosam<strong>in</strong>es can be done on <strong>the</strong> same tube.<br />
N-Nitrosopyrrolid<strong>in</strong>e<br />
930-55-2<br />
Florisil tube 500 mg with pre-tube<br />
2210 Florisil tube with pre-tube<br />
1-2 1000 GC-NPD 0,04 3,7<br />
IRSST<br />
371<br />
The recommended sampl<strong>in</strong>g volume is 400 to 1000 litres. The samples can be<br />
kept <strong>for</strong> 4 weeks <strong>in</strong> <strong>the</strong> dark at 4°C.The simulltaneous determ<strong>in</strong>ation of 8<br />
nitrosam<strong>in</strong>es can be done on <strong>the</strong> same tube.<br />
Phenanthrene<br />
85-01-8<br />
Millipore AP4003705 glass fiber filter<br />
pretreated <strong>in</strong> <strong>the</strong> laboratory <strong>in</strong> series with<br />
a Supelco 2-0264 Orbo-42 tube<br />
2187 Orbo 42 100/50 mg<br />
911 GF filter-37<br />
2 960 GC-MS 0,12<br />
IRSST<br />
225-2<br />
The sampl<strong>in</strong>g tra<strong>in</strong> consists of a cassette that will collect <strong>the</strong> PAHs <strong>in</strong> particulate<br />
<strong>for</strong>m, followed by a tube that will adsorb <strong>the</strong> PAHs <strong>in</strong> vapour <strong>for</strong>m. This tube is<br />
connected directly to <strong>the</strong> pump by Tygon tub<strong>in</strong>g. After sampl<strong>in</strong>g, <strong>the</strong> samples<br />
must be stored <strong>in</strong> <strong>the</strong> freezer protected from light. The tubes and filters must be<br />
shipped toge<strong>the</strong>r. Ten hydrocarbons are determ<strong>in</strong>ed simultaneously:<br />
acenaph<strong>the</strong>ne, fluorene, phenanthrene, anthracene, fluoran<strong>the</strong>ne, pyrene,<br />
chrysene, benz(a)anthracene, benzo(e)pyrene et le benzo(a)pyrene.<br />
Propionaldehyde 123-38-6<br />
Supelco 2-0257 Orbo 23 tube<br />
2186 Orbo 23 120/60 mg<br />
0,1 10 GC-MS 0,04<br />
IRSST<br />
323-1<br />
Be<strong>for</strong>e and after sampl<strong>in</strong>g, tubes must be stored <strong>in</strong> a freezer.<br />
Eleven aldehydes are determ<strong>in</strong>ed simultaneously: acetaldehyde,<br />
isobutyraldehyde, isovaleraldehyde, propionaldehyde, butyraldehyde, furfural,<br />
heptanal, hexanal, valeraldehyde, acrole<strong>in</strong> and <strong>for</strong>maldehyde. This method must<br />
not be used <strong>for</strong> <strong>the</strong> specific evaluation of <strong>for</strong>maldehyde; <strong>the</strong> methods to be used<br />
<strong>in</strong> this case are 295-1 and 357-1.<br />
Pyrene 129-00-0<br />
Millipore AP4003705 glass fiber filter<br />
pretreated <strong>in</strong> <strong>the</strong> laboratory <strong>in</strong> series with<br />
a Supelco 2-0264 Orbo-42 tube<br />
2187 Orbo 42 100/50 mg<br />
911 GF filter-37<br />
2 960 GC-MS 0,12<br />
IRSST<br />
225-2<br />
The sampl<strong>in</strong>g tra<strong>in</strong> consists of a cassette that will collect <strong>the</strong> PAHs <strong>in</strong> particulate<br />
<strong>for</strong>m, followed by a tube that will adsorb <strong>the</strong> PAHs <strong>in</strong> vapour <strong>for</strong>m. This tube is<br />
connected directly to <strong>the</strong> pump by Tygon tub<strong>in</strong>g. After sampl<strong>in</strong>g, <strong>the</strong> samples<br />
must be stored <strong>in</strong> <strong>the</strong> freezer protected from light. The tubes and filters must be<br />
shipped toge<strong>the</strong>r. Ten hydrocarbons are determ<strong>in</strong>ed simultaneously:<br />
acenaph<strong>the</strong>ne, fluorene, phenanthrene, anthracene, fluoran<strong>the</strong>ne, pyrene,<br />
chrysene, benz(a)anthracene, benzo(e)pyrene et le benzo(a)pyrene.<br />
Respirable combustible dust (RCD) Silver filter 25 mm (IRSST #950)<br />
1,7<br />
(nylon)<br />
2,75<br />
(GS3)<br />
1000 Grav<br />
CANMET The reference value <strong>for</strong> respirable combustible dust (RCD) accord<strong>in</strong>g to <strong>the</strong><br />
Regulation respect<strong>in</strong>g occupational health and safety <strong>in</strong> m<strong>in</strong>es is 0.6 mg/m³ (8-<br />
hour time-weigted average).<br />
Sevoflurane<br />
28523-86-6<br />
SKC ST226-81 Anasorb 747 tube<br />
2190 Anasorb 747 140/70 mg<br />
Max:<br />
0,2<br />
3<br />
GC-FID<br />
30 2,5<br />
IRSST<br />
355-1<br />
Sevoflurane must be specifically sampled due to <strong>the</strong> sampl<strong>in</strong>g device used and a<br />
specific desorption solvent.<br />
However, simultaneous sampl<strong>in</strong>g and analysis of desflurane is possible. A<br />
permissible exposure value (of <strong>the</strong> TWA type) of 80 mg/m³ has been proposed by<br />
<strong>the</strong> Swedish National Board of Occupational Safety and Health.<br />
Spores<br />
Cassette <strong>for</strong> spores with EMS 120520<br />
microscope slide<br />
931 Spore trap<br />
15 150 DLM<br />
IRSST<br />
367<br />
Spore counts and identification. The MRV is 13 spores/m³ <strong>for</strong> a sampl<strong>in</strong>g volume<br />
of 150 litres.