ROHS Substances table<br />

103<br />

ROHS Name<br />

CAS<br />

TWAEV<br />

STEV<br />

Ceil<strong>in</strong>g<br />

(mg/m³)<br />

Notes<br />

<strong>Sampl<strong>in</strong>g</strong><br />

Device<br />

Flow<br />

L/m<strong>in</strong><br />

Volume<br />

TWAEV<br />

STEV<br />

(L)<br />

Pr<strong>in</strong>ciple<br />

MRV<br />

µg<br />

CVa<br />

(%)<br />

#<br />

meth.<br />

Remarks<br />

p-Nitroanil<strong>in</strong>e<br />

100-01-6<br />

3 Pc Mixed cellulose ester filter<br />

1,0-3,0 350 HPLC-UV<br />

NIOSH<br />

5033<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Nitrobenzene<br />

98-95-3<br />

5 Pc Silica gel tube 100/50 mg<br />

0,01-1 150 GC-FID<br />

NIOSH<br />

2005<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

p-Nitrochlorobenzene<br />

100-00-5<br />

0,64 Pc Silica gel tube 150/75mg<br />

0,01-1 150 GC-FID<br />

NIOSH<br />

2005<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

4-Nitrodiphenyl<br />

92-93-3<br />

Pc<br />

C1<br />

RP<br />

EM<br />

OVS-2 tube with XAD-2 and glass fiber<br />

filter<br />

1,0 240 HPLC-UV<br />

OSHA<br />

PV2082<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Nitroethane<br />

79-24-3<br />

307 Two XAD-2 tubes <strong>in</strong> series<br />

0,01- 3 GC-FID<br />

NIOSH<br />

2526<br />

0,05<br />

At <strong>the</strong> end of sampl<strong>in</strong>g, <strong>the</strong> front tube must be separated from <strong>the</strong> back tube to<br />

avoid migration. Reseal each end of <strong>the</strong> tubes. Contact <strong>the</strong> IRSST be<strong>for</strong>e<br />

sampl<strong>in</strong>g.<br />

Nitrogen<br />

7727-37-9<br />

Ax<br />

DRI-elec<br />

IRSST<br />

26-C<br />

S<strong>in</strong>ce azote is a simple asphyxiant, oxygen <strong>in</strong> <strong>the</strong> air is quantified <strong>in</strong> <strong>the</strong> field with<br />

a direct-read<strong>in</strong>g <strong>in</strong>strument (DRI).<br />

The m<strong>in</strong>imum reported value is 1% oxygen. The reference method corresponds<br />

to calibration of <strong>the</strong> DRI.<br />

Nitrogen dioxide<br />

10102-44-0<br />

5,6 DRI-elec<br />

IRSST<br />

30-B<br />

Refer to <strong>the</strong> user's guide accompany<strong>in</strong>g <strong>the</strong> <strong>in</strong>strument.<br />

Nitrogen dioxide is quantified <strong>in</strong> <strong>the</strong> field with a direct-read<strong>in</strong>g <strong>in</strong>strument (DRI).<br />

The m<strong>in</strong>imum reported value is 0.9 mg/m³ (0.5 ppm). The reference method<br />

corresponds to calibration of <strong>the</strong> DRI.<br />

Nitrogen monoxide<br />

10102-43-9<br />

31 DRI-elec<br />

IRSST<br />

06-A<br />

Refer to <strong>the</strong> user's guide accompany<strong>in</strong>g <strong>the</strong> <strong>in</strong>strument.<br />

Nitric oxide is quantified <strong>in</strong> <strong>the</strong> field with a direct-read<strong>in</strong>g <strong>in</strong>strument (DRI). The<br />

m<strong>in</strong>imum reported value is 1.2 mg/m³ (1 ppm). The reference method<br />

corresponds to calibration of <strong>the</strong> DRI.. Azote monoxyde quantified with DRI.<br />

Nitrogen trifluoride<br />

7783-54-2<br />

29 DRI-IR<br />

OSHA<br />

IMIS1907<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Nitroglycer<strong>in</strong> (NG)<br />

55-63-0<br />

--<br />

--<br />

1,86<br />

Pc<br />

RP<br />

Tenax tube, 100/50 mg<br />

0,2-1 100 GC-ECD<br />

NIOSH<br />

2507<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g. Can be kept <strong>for</strong> at least 25 days at 25°C.