ROHS Substances table<br />
132<br />
ROHS Name<br />
CAS<br />
TWAEV<br />
STEV<br />
Ceil<strong>in</strong>g<br />
(mg/m³)<br />
Notes<br />
<strong>Sampl<strong>in</strong>g</strong><br />
Device<br />
Flow<br />
L/m<strong>in</strong><br />
Volume<br />
TWAEV<br />
STEV<br />
(L)<br />
Pr<strong>in</strong>ciple<br />
MRV<br />
µg<br />
CVa<br />
(%)<br />
#<br />
meth.<br />
Remarks<br />
Z<strong>in</strong>c chloride, fume<br />
7646-85-7<br />
1 Mixed cellulose ester filter, 0.8µm, 25 and 1,5 180 ICP-MS 1 3,19 IRSST<br />
362<br />
37 mm.<br />
905 MCE filter-37<br />
915 MCE filter-25<br />
Cassettes 913 or 916, whose filters are preweighed, can also be used. For<br />
surface wipe sampl<strong>in</strong>g, contact Laboratory Customer Service.<br />
The analytical results are expressed as total z<strong>in</strong>c. A stoichiometric factor must be<br />
applied.<br />
Z<strong>in</strong>c chromates [13530-<br />
65-9;11103-86-9; 37300-<br />
23-5] (as Cr)<br />
13530-65-9<br />
0,01 C1<br />
RP<br />
EM<br />
S<br />
PALL CA28149-306 v<strong>in</strong>yl/acrylic<br />
copolymer filter<br />
926 V<strong>in</strong>yl/acrylic copolymer filter<br />
1,5 à 4 360 IC-VIS 0,04 4,4 IRSST<br />
365<br />
For surface wipe sampl<strong>in</strong>g, contact Laboratory Customer Service.<br />
The analytical results are expressed as total water-<strong>in</strong>soluble chromium VI.<br />
Surface tests <strong>for</strong> chromates can be carried out, and <strong>the</strong> required equipment (kit<br />
#2625) is available at <strong>the</strong> IRSST. See communiqué 2008-06 on our Web site.<br />
Analysis time of 8 days <strong>for</strong> weld<strong>in</strong>g fumes and 10 days <strong>for</strong> <strong>the</strong> o<strong>the</strong>r processes<br />
follow<strong>in</strong>g <strong>the</strong> sampl<strong>in</strong>g date. Ship all samples by rapid courier with<strong>in</strong> a period not<br />
exceed<strong>in</strong>g 24 hours after sampl<strong>in</strong>g.<br />
Any substance that produces a response on <strong>the</strong> detector at 540 nm and that has<br />
a retention time similar to Cr VI is a potential <strong>in</strong>terference.<br />
Z<strong>in</strong>c stearate<br />
557-05-1<br />
10 SKC 225-8-01-1 or 225-8-04 polyv<strong>in</strong>yl 1,5 180 Grav 25 4,9 IRSST<br />
48-1<br />
chloride filter<br />
902 PVC filter-37<br />
914 PVC filter-25<br />
Additional <strong>in</strong><strong>for</strong>mation is available <strong>in</strong> Info-Labo 91-03. The weight measurement<br />
method <strong>for</strong> dusts is by def<strong>in</strong>ition non-specific.<br />
Z<strong>in</strong>c, oxide, Dust<br />
1314-13-2<br />
10 Pt SKC 225-8-01-1 or 225-8-04 polyv<strong>in</strong>yl 1,5 180 Grav 25 4,9 IRSST<br />
48-1<br />
chloride filter<br />
902 PVC filter-37<br />
914 PVC filter-25<br />
Additional <strong>in</strong><strong>for</strong>mation is available <strong>in</strong> Info-Labo 91-03. The weight measurement<br />
method <strong>for</strong> dusts is by def<strong>in</strong>ition non-specific.<br />
Z<strong>in</strong>c, oxide, Fume<br />
1314-13-2<br />
5<br />
10<br />
Mixed cellulose ester filter, 0.8µm, 25 and<br />
37 mm.<br />
905 MCE filter-37<br />
915 MCE filter-25<br />
1,5 180 ICP-MS 1 3,19 IRSST<br />
362<br />
Cassettes 913 or 916, whose filters are preweighed, can also be used. For<br />
surface wipe sampl<strong>in</strong>g, contact Laboratory Customer Service.<br />
The analytical results are expressed as total z<strong>in</strong>c. A stoichiometric factor must be<br />
applied.<br />
Zirconium [7440-67-7]<br />
and compounds (as Zr)<br />
5<br />
10<br />
Mixed cellulose ester filter<br />
2 960 FAAS<br />
30<br />
OSHA<br />
ID121<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Fluoride, chloride, ammonium, sulfate and nitrate salts and nickel bromide may<br />
cause <strong>in</strong>terference dur<strong>in</strong>g <strong>the</strong> analysis.