ROHS Substances table<br />
88<br />
ROHS Name<br />
CAS<br />
TWAEV<br />
STEV<br />
Ceil<strong>in</strong>g<br />
(mg/m³)<br />
Notes<br />
<strong>Sampl<strong>in</strong>g</strong><br />
Device<br />
Flow<br />
L/m<strong>in</strong><br />
Volume<br />
TWAEV<br />
STEV<br />
(L)<br />
Pr<strong>in</strong>ciple<br />
MRV<br />
µg<br />
CVa<br />
(%)<br />
#<br />
meth.<br />
Remarks<br />
2-Hydroxypropyl<br />
acrylate<br />
999-61-1<br />
2,8 Pc Activated charcoal tube impregnated with 0,1 10 GC-FID<br />
OSHA<br />
PV2078<br />
4-tert-butylcatechol (TBC)<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Indene<br />
95-13-6<br />
48 Activated charcoal tube 100/50mg<br />
0,2 10 GC-FID<br />
OSHA<br />
07<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
OSHA 07 method is <strong>for</strong> organic vapors and can be adapted to <strong>in</strong>dene.<br />
Indium [7440-74-6] and<br />
compounds (as In)<br />
0,1 Mixed cellulose ester filter<br />
2 960 FAAS<br />
OSHA<br />
ID121<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Iod<strong>in</strong>e<br />
7553-56-2<br />
--<br />
--<br />
1<br />
RP Treated SKC-226-80 charcoal tube<br />
0,5 7,5 SE<br />
OSHA<br />
ID-212<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Iodo<strong>for</strong>m<br />
75-47-8<br />
10 Glass fiber filter <strong>in</strong> series with an XAD-4 0,1 10 GC-ECD<br />
OSHA<br />
IMIS1517<br />
tube<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Iron pentacarbonyl (as<br />
Fe)<br />
13463-40-6<br />
0,23<br />
0,45<br />
Glass fritted tip imp<strong>in</strong>ger conta<strong>in</strong><strong>in</strong>g 10 mL<br />
of a mixture of hydrochloric acid and<br />
iod<strong>in</strong>e-potassium iodide<br />
1 480 Colo<br />
15<br />
OSHA<br />
IMIS1521<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Iron salts, soluble (as<br />
Fe)<br />
1<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
No support<strong>in</strong>g reference is suggested <strong>for</strong> this product.<br />
Iron trioxide, dust and<br />
fume (as Fe)<br />
1309-37-1<br />
5 Mixed cellulose ester filter, 0.8µm, 25 and 1,5 180 ICP-MS 10 2,95 IRSST<br />
362<br />
37 mm.<br />
905 MCE filter-37<br />
915 MCE filter-25<br />
Cassettes 913 or 916, whose filters are preweighed, can also be used. For<br />
surface wipe sampl<strong>in</strong>g, contact Laboratory Customer Service.<br />
The analytical results are expressed as total iron.<br />
Isoamyl alcohol<br />
123-51-3<br />
361<br />
452<br />
Activated charcoal tube 100/50 mg<br />
0,01-<br />
0,2<br />
10<br />
3<br />
GC-FID<br />
NIOSH<br />
1405<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.