ROHS Substances table<br />

88<br />

ROHS Name<br />

CAS<br />

TWAEV<br />

STEV<br />

Ceil<strong>in</strong>g<br />

(mg/m³)<br />

Notes<br />

<strong>Sampl<strong>in</strong>g</strong><br />

Device<br />

Flow<br />

L/m<strong>in</strong><br />

Volume<br />

TWAEV<br />

STEV<br />

(L)<br />

Pr<strong>in</strong>ciple<br />

MRV<br />

µg<br />

CVa<br />

(%)<br />

#<br />

meth.<br />

Remarks<br />

2-Hydroxypropyl<br />

acrylate<br />

999-61-1<br />

2,8 Pc Activated charcoal tube impregnated with 0,1 10 GC-FID<br />

OSHA<br />

PV2078<br />

4-tert-butylcatechol (TBC)<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Indene<br />

95-13-6<br />

48 Activated charcoal tube 100/50mg<br />

0,2 10 GC-FID<br />

OSHA<br />

07<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

OSHA 07 method is <strong>for</strong> organic vapors and can be adapted to <strong>in</strong>dene.<br />

Indium [7440-74-6] and<br />

compounds (as In)<br />

0,1 Mixed cellulose ester filter<br />

2 960 FAAS<br />

OSHA<br />

ID121<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Iod<strong>in</strong>e<br />

7553-56-2<br />

--<br />

--<br />

1<br />

RP Treated SKC-226-80 charcoal tube<br />

0,5 7,5 SE<br />

OSHA<br />

ID-212<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Iodo<strong>for</strong>m<br />

75-47-8<br />

10 Glass fiber filter <strong>in</strong> series with an XAD-4 0,1 10 GC-ECD<br />

OSHA<br />

IMIS1517<br />

tube<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Iron pentacarbonyl (as<br />

Fe)<br />

13463-40-6<br />

0,23<br />

0,45<br />

Glass fritted tip imp<strong>in</strong>ger conta<strong>in</strong><strong>in</strong>g 10 mL<br />

of a mixture of hydrochloric acid and<br />

iod<strong>in</strong>e-potassium iodide<br />

1 480 Colo<br />

15<br />

OSHA<br />

IMIS1521<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Iron salts, soluble (as<br />

Fe)<br />

1<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

No support<strong>in</strong>g reference is suggested <strong>for</strong> this product.<br />

Iron trioxide, dust and<br />

fume (as Fe)<br />

1309-37-1<br />

5 Mixed cellulose ester filter, 0.8µm, 25 and 1,5 180 ICP-MS 10 2,95 IRSST<br />

362<br />

37 mm.<br />

905 MCE filter-37<br />

915 MCE filter-25<br />

Cassettes 913 or 916, whose filters are preweighed, can also be used. For<br />

surface wipe sampl<strong>in</strong>g, contact Laboratory Customer Service.<br />

The analytical results are expressed as total iron.<br />

Isoamyl alcohol<br />

123-51-3<br />

361<br />

452<br />

Activated charcoal tube 100/50 mg<br />

0,01-<br />

0,2<br />

10<br />

3<br />

GC-FID<br />

NIOSH<br />

1405<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.