Applications 4<br />

Two-prism pole 40.1<br />

1. To enter the two-prism pole function, press [3]<br />

or select 2Prism Pole in the Offset menu.<br />

2. Sight the first prism and press [MSR1] or [MSR2].<br />

3. Sight the second prism and press [MSR1] or<br />

[MSR2].<br />

4. Enter the distance between the second prism<br />

and the target point. Alternatively, if you do<br />

not need QA information, you can leave the<br />

distance between the first and the second<br />

prism blank.<br />

5. If you do enter a P1-P2 distance, the QA<br />

screen appears. Compare the entered value and<br />

the measured distance to check the accuracy of<br />

the observation.<br />

6. To record the point, press [ENT] or the OK<br />

softkey.<br />

Sample records<br />

SS,14,0.0000,38.9200,271.0350,89.2630,11:04:15,DITCH<br />

CO,2Prism O/S: P1-P2= 0.5090( 0.5060) P2-Tgt= 0.5020<br />

In this sample data, 0.5090 is the measured value. 0.5060 is the entered value.<br />

Pulse Laser Station <strong>NPL</strong>-302 Series Instruction <strong>Manual</strong> 107