5 Menu Key<br />

Distance 51.2<br />

To open the Distance menu, press [2] or select<br />

Distance in the Settings menu.<br />

Scale<br />

T-P corr.<br />

Sea Level<br />

C&R corr.<br />

Numeric value between<br />

0.999600 and 1.000400<br />

ON/OFF<br />

ON/OFF<br />

OFF/0.132/0.200<br />

The Scale, T-P corr., Sea Level, and C&R corr. job settings cannot be changed once<br />

a job is created.<br />

Temperature and Pressure corrections<br />

SD Slope dist. (before adj.)<br />

SD' Slope dist. (after adj.)<br />

K<br />

Compensation coefficient<br />

P<br />

Pressure (hPa)<br />

T<br />

Temperature (°C)<br />

10000.0<br />

106 × P × --------------------------------------------<br />

⎝<br />

⎛ 13.5951 × 980.665⎠<br />

⎞<br />

K = 275 – ---------------------------------------------------------------------------<br />

237 + T<br />

SD' = ⎛1<br />

+ --------------------<br />

K ⎞ × SD<br />

⎝ 1000000⎠<br />

Sea Level correction<br />

HD Horizontal dist. (before adj.)<br />

HD' Horizontal dist. (after adj.)<br />

Z STN<br />

R e<br />

Instrument-Z<br />

6370 km<br />

HD × R<br />

HD' = ------------------------ e<br />

R e + Z STN<br />