3 Getting Started<br />

Turning the Instrument On and Off 3.1<br />

Turning on the instrument 31.1<br />

1. To turn on the instrument, press [PWR]. The<br />

start-up screen appears. It shows the current<br />

temperature, pressure, date, and time.<br />

2. To change the temperature or pressure value,<br />

use [^] or [v] to move the cursor to the field that<br />

you want to change. Then press [ENT].<br />

3. If you want to initialize the horizontal angle,<br />

rotate the alidade.<br />

4. Tilt the telescope until it passes the horizontal<br />

position on Face-1.<br />

If you have entered your name or your company’s<br />

name in the Owner’s detail field, the text from this<br />

field appears on the start-up screen. To set the<br />

Owner’s detail field, go to MENU > Settings<br />

> Other. For more information, see page 140.<br />

Once you start to use an initialized HA, you must rotate the alidade to initialize the<br />

HA every time you turn on the instrument. If you do this, you can maintain a fixed HA<br />

orientation even if the instrument has moved while it is turned off.<br />

If you tilt the telescope before you rotate the alidade, the horizontal angle is not<br />

initialized, and the instrument uses the previous HA reading.<br />

28 Pulse Laser Station <strong>NPL</strong>-302 Series Instruction <strong>Manual</strong>