2 Preparation<br />

When the instrument is centered, tighten the mounting screw.<br />

– If the displacement of the station point is major, repeat this procedure from<br />

Step 2.<br />

Centering using a plumb bob 20.1<br />

1. Set up the instrument on the tripod. For detailed instructions, see Setting Up the<br />

Tripod, page 14.<br />

2. Hang the plumb line on the hook of the tripod mounting screw.<br />

3. Adjust the length of the plumb line so that the tip of the plumb bob is at the<br />

height of the station point.<br />

4. Loosen the tripod mounting screw slightly.<br />

5. Using both hands to support the outer side of the leveling base, carefully slide<br />

the instrument about on the tripod head until the tip of the plumb bob is<br />

positioned over the exact center of the station point.<br />

Note – To confirm that the instrument is precisely aligned, check its position<br />

from two directions at right angles to each other.<br />

Leveling 2.1<br />

When you level the instrument, you make the vertical axis of the instrument exactly<br />

vertical. To level the instrument, use the plate level.<br />

To level the instrument:<br />

1. Loosen the upper plate clamp.<br />

2. Rotate the alidade until the plate level is<br />

parallel with any two of the leveling<br />

A<br />

screws (B and C).<br />

3. Use leveling screws B and C to move the<br />

bubble into the center of the level.<br />

4. Rotate the alidade approximately 90°.<br />

B<br />

C<br />

1<br />

16 Pulse Laser Station <strong>NPL</strong>-302 Series Instruction <strong>Manual</strong>