There are two air emission standards that have been promulgated that apply to<br />

<strong>the</strong> <strong>Base</strong> <strong>Metals</strong> <strong>Smelting</strong> <strong>Sector</strong>:<br />

• Hazardous Air Pollutants <strong>for</strong> Primary Lead <strong>Smelting</strong> (Table 30)<br />

• Inorganic Arsenic Emissions from Primary Copper Smelters (Table 31)<br />

The EPA also limits arsenic emissions by controlling emissions of particulate<br />

matter.<br />

Table 30: US National Emission Standard <strong>for</strong> Primary Lead <strong>Smelting</strong> 130<br />

Source Limit Conditions<br />

Aggregated lead emissions from<br />

<strong>the</strong> following process and<br />

process fugitive sources:<br />

1. Sinter machine;<br />

2. Blast furnace;<br />

3. Dross furnace;<br />

4. Dross furnace charging<br />

location;<br />

5. Blast and dross furnace<br />

tapping locations;<br />

6. Sinter machine charging<br />

location;<br />

7. Sinter machine discharge<br />

end;<br />

8. Sinter crushing and sizing<br />

equipment;<br />

9. Sinter machine area.<br />

500 g Pb /Mg of lead produced<br />

(500 g/tonne)<br />

(1.0 lb/ton of lead produced)<br />

The lead compound emission<br />

limit is a surrogate <strong>for</strong> all metal<br />

HAP's and will apply to both<br />

existing and new sources.<br />

Requires that <strong>the</strong> charging,<br />

tapping, and sinter handling<br />

sources identified above (items 4<br />

through 8) be equipped with a<br />

hood ventilated to a control<br />

device.<br />

Each primary lead smelter would<br />

be required to develop a<br />

Standard Operating Procedures<br />

(SOP) manual <strong>for</strong> fugitive dust<br />

sources that details procedures<br />

to limit fugitive dust emissions.<br />

130 40 CFR, Part 63, Subpart TTT (63.1541-63.63.1550) National Emission Standards <strong>for</strong><br />

Hazardous Air Pollutants <strong>for</strong> Primary Lead <strong>Smelting</strong> (published in <strong>the</strong> Federal Register on June 4,<br />

1999). URL: www.access.gpo.gov/nara/cfr/waisidx_99/40cfrv9_99.html<br />