Please set the scale of the analog monitor channel<br />

1 at SEt-08. The setting range is 1 to 65535 /V and<br />

the default value is 500.<br />

Please set the scale of the analog monitor channel<br />

2 at SEt-09. The setting range is 1 to 65535 /V and<br />

the default value is 500.<br />

If the scale of the analog monitor channel 1 is set to 500 of the speed<br />

command (0), the speed command of the controller that corresponds<br />

to the monitor output 1V is 500 RPM. Since the maximum output is 10<br />

V, the speed can be monitored up to 5000 RPM. Therefore, the<br />

monitoring range of the overall speed command is ±5000 RPM.<br />

If the scale of the analog monitor channel 2 is 1000 of the position<br />

command (2), the position command of the controller that<br />

corresponds to the monitor output of 1V is 1000 pulses. As the<br />

maximum output is 10 V, the position command can be checked up to<br />

10000 pulses. Therefore, the monitoring range of the overall position<br />

command is ±10000 pulses..<br />