SEt-75 Overload Curve Level<br />

• Setting range: 50 to 300%<br />

• <strong>User</strong> Default: 100<br />

• Changes while the servo is OFF<br />

The level of overload curves of driver can be controlled.<br />

SEt-76 Output Signal Assignment 1<br />

• Setting range: 0 x 0000 to 0 x 3333<br />

• <strong>User</strong> Default: 0 x 0321<br />

• Change while the servo is OFF, and turn off the power and turn it back on<br />

Output signals to be used at the CN1 connector’s output pins from<br />

DO#1 to DO#3 should be allocated.<br />

Output Signal Allocation Table<br />

Parameter Fourth Digit Third Digit Second Digit First Digit<br />

SEt-76 /V-COM /BK /TG-ON /P-COM<br />

SEt-77 /WARN /NEAR /V-LMT /T-LMT<br />

Put 1 in the first digit of SEt-76 to allocate /P-COM signal to the DO#1<br />

pin.<br />

Put 3 in the fourth digit of SEt-77 to use /WARN function through DO#3<br />

pin.<br />

Setting 0 makes the system always invalid and there is no value to<br />

make the system always valid, which is different from the input case.<br />

SEt-77 Output Signal Assignment 2<br />

• Setting range: 0 x 0000 to 0 x 3333<br />

• <strong>User</strong> Default: 0 x 0000<br />

• Change while the servo is OFF, and turn off the power and turn it back on<br />