Put 3 in the second digit of SEt-62 to allocate the /INHIB signal to DI#3<br />

pin.<br />

When 9 is set, it is always valid and when 0 is set, it is always invalid.<br />

For instance, to keep /SV-ON always valid when the power is on<br />

regardless of the wiring, put 9 in the first digit of SEt-59.<br />

SEt-60 Input Signal Assignment 2<br />

• Setting range: 0 x 0 to 0 x 9999<br />

• <strong>User</strong> Default: 0 x 0765<br />

• Change while the servo is OFF, and turn off the power and turn it back on<br />

SEt-61 Input Signal Assignment 3<br />

• Setting range: 0 x 0 to 0 x 9999<br />

• <strong>User</strong> Default: 0 x 0000<br />

• Change while the servo is OFF, and turn off the power and turn it back on<br />

SEt-62 Input Signal Assignment 4<br />

• Setting range: 0 x 0 to 0 x 9999<br />

• <strong>User</strong> Default: 0 x 0000<br />

• Change while the servo is OFF, and turn off the power and turn it back on<br />

SEt-63 Input Signal Assignment 5<br />

• Setting range: 0 x 0 to 0 x 9999<br />

• <strong>User</strong> Default: 0 x 0080<br />

• Change while the servo is OFF, and turn off the power and turn it back on<br />