14.11.2014 Views

CSDP Plus Servo Drive User Manual

CSDP Plus Servo Drive User Manual

CSDP Plus Servo Drive User Manual

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SEt-43(2) P-OT Signal Function Selection<br />

• Setting range: 0 x 0 to 0 x 1<br />

• <strong>User</strong> Default: 0 x 1<br />

• Change while the servo is OFF, and turn off the power and turn it back on<br />

The set values are as follows.<br />

0: Forbid forward revolution with P-OT signal<br />

1: Always approve forward revolving operation<br />

SEt-43(3) N-OT Signal Function Selection<br />

• Setting range: 0 x 0 to 0 x 1<br />

• <strong>User</strong> Default: 0 x 1<br />

• Change while the servo is OFF, and turn off the power and turn it back on<br />

The set values are as follows.<br />

0: Forbid reverse revolution with N-OT signal.<br />

1: Always approve reverse revolving operation<br />

SEt-43(4) TG-ON Signal Function Selection<br />

• Setting range: 0 x 0 to 0 x 1<br />

• <strong>User</strong> Default: 0 x 0<br />

• Change while the servo is OFF, and turn off the power and turn it back on<br />

The set values are as follows.<br />

0: ON when the speed is faster than the zero speed level (SEt-16)<br />

1: ON when the current is higher than the current limit<br />

(SEt-10, SEt-11, SEt-12, SEt-13)<br />

156

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!