When P-OT signal is set to the forward revolution limit signal (second<br />

digit of SEt-43) and the P-OT signal is received during the motor’s<br />

forward revolution, the motor will stop in emergency. This parameter<br />

is the value of the torque at that time.<br />

SEt-15 Reverse Emergency Stop Torque<br />

• Setting range: 0 to 300%<br />

• <strong>User</strong> Default: 300<br />

• Changes anytime<br />

When N-OT signal is the reverse revolution limit signal (third digit of<br />

SEt-43) and N-OT signal is received during the motor’s reverse<br />

revolution, the motor stops in emergency. This parameter is the value<br />

of the torque at that time.<br />

SEt-16 TG-ON Speed Level<br />

• Setting range: 1 to 5000 RPM<br />

• <strong>User</strong> Default: 20<br />

• Changes anytime<br />

This parameter is the speed level that switches on the /TG-ON output.<br />

It is valid only when the TG-ON signal function (fourth digit of SEt-43)<br />

is set 0. If the motor speed exceeds the preset value of this parameter,<br />

/TG-ON signal will be ON.<br />