SEt-45(2) Speed Command Offset Auto<br />

Adjustment<br />

• Setting range: 0 x 0 to 0 x 1<br />

• <strong>User</strong> Default: 0 x 0<br />

• Changes while the servo is OFF<br />

The set values are as follows.<br />

0: Analog Speed Command Offset<br />

1: Current Offset when the servo is OFF<br />

2: Current Offset when the servo is ON<br />

SEt-45(3) Speed Limit Method<br />

• Setting range: 0 x 0 to 0 x 3<br />

• <strong>User</strong> Default: 0 x 0<br />

• Changes while the servo is OFF<br />

The set values are as follows.<br />

0: Motor Maximum Speed<br />

1: SEt-67 Value<br />

2: Analog Speed Command<br />

3: The smaller value between the motor maximum speed and SEt-67<br />

SEt-45(4) Motor Revolving Direction<br />

• Setting range: 0 x 0 to 0 x 1<br />

• <strong>User</strong> Default: 0 x 0<br />

• Changes while the servo is OFF<br />

This parameter determines the revolving direction of the motor. The<br />

set values are as follows.<br />

0: Forward Direction<br />

1: Reverse Direction<br />