If the CN1 connector pins where the zero clamp function is allocated<br />

are ON, the voltage command below the level set at SEt-17 will be<br />

ignored. When the value of the speed command surpasses this level<br />

again, the motor will accelerate to the value of the command.<br />

In Speed Function<br />

/V-COM signal displays that the error between the motor revolution<br />

speed and the speed command value is kept within a certain range.<br />

This signal can be used as an interlock signal at the controller just as<br />

the position completion detection /P-COM signal at the position<br />

control mode can.<br />

Please set the decision range for in speed match at<br />

SEt-18. The setting range is 0 to 1000 RPM and the<br />

default value is 10.<br />

If the in speed is 100 and the speed command is 2000 RPM, /V-COM<br />

signal is ON and displayed when the actual revolution speed is 1900<br />

RPM or higher and 2100 RPM or lower.<br />