Default Torque Bias<br />

Default torque bias prevents a fall due to gravity of the vertical load<br />

during the initial operation.<br />

When the load is vertical and the servo<br />

ON signal is applied to activate the<br />

motor, the load can fall because of<br />

gravity. And when the servo ON, servo<br />

OFF signals are applied, the motor brake<br />

should be applied or released. If the<br />

timing is not properly adjusted, the load<br />

can fall momentarily, causing vibration<br />

in the machine. This characteristics of<br />

the vertical load causes overshoot and<br />

postpones position completion.<br />

Moreover, the servo alarm can go off as<br />

the system tries to activate the motor<br />

while the brake is applied.<br />

Default torque bias is used to prevent the load from falling by gravity<br />

during the process of controlling the vertical load. The default torque<br />

equal to the falling load is applied to the motor in a reverse direction of<br />

the falling motion when the servo ON signal is applied. If default<br />

torque bias is properly set according to the falling force of the load, the<br />

falling of the vertical load can be prevented in the early stage of the<br />

operation.<br />

By adjusting torque command offset (SEt-64 and<br />

SEt-65), revolution of the motor can be prevented.<br />

ATTENTION<br />

In case of controlling a vertical load, please use brake motor<br />

or install braking device to use the motor.<br />

98