SEt-24 Encoder Output Ratio Denominator<br />

• Setting range: 1 to 65535 pulse<br />

• Factory Default: 2500<br />

• Changes while the servo is OFF<br />

ATTENTION<br />

The servo drive output pulse cannot output to the outside A<br />

and B phase pulses higher than the number of encoder pulses<br />

per the motor’s revolution. If the motor-mounted encoder<br />

generates 2048 PPR, the pulse from the servo drive to the<br />

outside cannot exceed 2048 pulses per the motor’s<br />

revolution.<br />

SEt-25 Jog Command Speed<br />

• Setting range: 0 to 5000 RPM<br />

• <strong>User</strong> Default: 500<br />

• Changes anytime<br />

This parameter is the command speed for a jog operation or a pilot<br />

operation.<br />