6<br />

Application<br />

Motor Stop<br />

The servo drive aborts the operation and stops the motor under the<br />

following circumstances except for the case where the motor is<br />

stopped by normal operation.<br />

• <strong>Servo</strong> Alarm Occurs<br />

• Overtravel Occurs<br />

The methods to stop the motor can be set up depending on the<br />

reasons for the stoppage.<br />

• Stop by dynamic brake<br />

• Control stop as in normal operation<br />

Overtravel<br />

If the load moves out of the movement range during operation, the<br />

load system can be damaged. The breakage of the load system can be<br />

prevented by installing limit sensors at the end of the movement<br />

range.<br />

Please make sure the load can move within the range that won’t touch<br />

the sensors during operation. If the load moves out of the movement<br />

range and the sensor generates a signal because of an unknown error,<br />

the servo drive can stop the motor and protect the load system. The<br />

signal emitted from the limit sensors while the motor revolves in the<br />

forward direction is the P-OT signal, and is the N-OT signal while the<br />

motor revolves in the reverse direction.<br />