SEt-07 Position Feedforward Filter<br />

• Setting range: 0 to 5000 rad/s<br />

• <strong>User</strong> Default: 0<br />

• Changes anytime<br />

The filter is used to feedforward the differentiated position command.<br />

This parameter is the cut-off frequency of the filter. If position<br />

feedforward gain (SEt-34) is 0, this parameter is not valid. In the case<br />

of an overshoot, please set the parameter to 0.<br />

Please refer to the diagram below for the information about the usage<br />

and the setting position of SEt-07.<br />

SEt-08 DA Monitor Channel 1 Scale<br />

• Setting range: 1 to 65535/V<br />

• <strong>User</strong> Default: 500<br />

• Changes anytime<br />

The servo drive can display the analog monitor signals with which the<br />

user can check the actual control status through an oscilloscope.<br />

Set the scale unit of analog monitor channel 1 at<br />

SEt-08.<br />

137