Chapter 1 PUMPING INSTALLATION<br />

A steep H-Q curve may be preferred for pumping water from the river where fluctuation of river<br />

water level is prevalent, thus constant pump discharge is expected.<br />

1.3 SYSTEM CHARACTERISTICS<br />

Pump is normally designed with its best efficiency at the intersection of the pump head-discharge<br />

curve <strong>and</strong> the system head curve. The system head curve can be represented graphically by<br />

combining the static head <strong>and</strong> system friction head as shown below.<br />

1.4 PUMPING ARRANGEMENTS<br />

Fig. 1.5 Pump performance characteristic<br />

It is a common practice to have a multiple-pumps pumping system to cater for the duty required.<br />

Pumps may be arranged to operate independently with individual delivery system or to operate in<br />

parallel in a single delivery pipeline. However, when operated in parallel, because of the additional<br />

resistance incurred it is unlikely to achieve the theoretical increase in flow rate. Where large<br />

quantities of discharge are required at high heads, multiple pumps in series may be used. However,<br />

such system is rarely common in DID application.<br />

1.5 PUMP AUTOMATIC CONTROL<br />

Hitherto, most of the pumping stations are provided with automatic control system with manual<br />

override. A control based on water level in the pump sump or in the discharge canal is commonly<br />

used as a control constant for irrigation <strong>and</strong> drainage applications. The automatic level-responsive<br />

pump control is designed for (a) pump-up mode in filling up the canal to the designed full supply<br />

level for irrigation purpose or (b) pump-down mode in keeping the sump water level under a certain<br />

level for flood control.<br />

For reliable automatic control, especially in l<strong>and</strong> drainage pumping station, due consideration shall be<br />

given to the consequences of the failure of any station components in the design stage. All practical<br />

provisions should be made for continual station operation under such component failure conditions.<br />

Critical components may be provided in duplicate as st<strong>and</strong>by <strong>and</strong> additional pumping unit shall be<br />

provided. For larger pumping stations, st<strong>and</strong>by generating-set may be provided as an alternative<br />

source of power supply in the event of power outage.<br />