3GPP TS 27.007 version 11.8.0 Release 11<br />

102<br />

ETSI TS 127 007 V11.8.0 (2013-10)<br />

Char IRA (dec) Comment (+ some known key symbols)<br />

[ 91 soft key 1<br />

] 93 soft key 2<br />

^ 94 up arrow<br />

, : integer type<br />

0...255 0... 25.5 seconds (default values are manufacturer specific, but should be so long that a normal MT<br />

can handle keystrokes correctly)<br />

Implementation<br />

Mandatory for MT not supporting the +CPIN command and supporting AT commands only.<br />

8.8 Display control +CDIS<br />

Table 68: +CDIS parameter command syntax<br />

Command<br />

+CDIS=[[,[,...]]]<br />

+CDIS<br />

+CDIS=<br />

Possible response(s)<br />

+CME ERROR: <br />

+CDIS: [,[,...]]<br />

+CME ERROR: <br />

+CDIS: [,[,...]]<br />

+CME ERROR: <br />

Description<br />

Set command is used to write the conten<strong>ts</strong> of MT text type display elemen<strong>ts</strong>. An element can consist of one character or<br />

several characters. The order of element parameters should follow the rule: first is the element in upper left<br />

corner, second is the next element to the right and so on. The last element is the element in lower right corner. The<br />

number of elemen<strong>ts</strong> is MT specific. If MT does not allow writing to i<strong>ts</strong> display or MT is not currently reachable,<br />

+CME ERROR: is returned. Refer subclause 9.2 for values. If certain element is not writable, setting<br />

of it should be ignored. If element parameter is empty field, element shall remain in the previous value.<br />

NOTE 1: This command cannot be used to write to a display which sum of element lengths exceed the length of the<br />

command line buffer of the TA.<br />

Read command returns the conten<strong>ts</strong> of MT display elemen<strong>ts</strong>. If field is empty (not empty string), MT does not<br />

allow the reading of corresponding element. If MT is not currently reachable, +CME ERROR: is returned.<br />

Refer subclause 9.2 for values.<br />

Test command returns maximum length of each display element. If MT does not offer the length of elemen<strong>ts</strong>,<br />

fields should be empty. If MT is not currently reachable, +CME ERROR: is returned. Refer<br />

subclause 9.2 for values.<br />

NOTE 2: MT manufacturer should offer the order and maximum length of elemen<strong>ts</strong>.<br />

Defined values<br />

: string type parameter using character set specified by command Select TE Character Set +CSCS<br />

: integer type parameter giving the maximum length of corresponding parameter<br />

Implementation<br />

Optional.<br />

ETSI