3GPP TS 27.007 version 11.8.0 Release 11<br />

168<br />

ETSI TS 127 007 V11.8.0 (2013-10)<br />

+CBCAP=<br />

+CBCAP: (list of supported s),(list of supported<br />

s)<br />

Description<br />

Set command enables reporting upon change in battery capacity level, with unsolicited result code +CBCAP: .<br />

Consecutive repor<strong>ts</strong> never show same value of .<br />

Read command returns the status of result code presentation and the current battery capacity level.<br />

Test command returns values supported as compound values.<br />

Defined values<br />

: integer type. Enables and disables reporting of changes in the battery capacity level.<br />

0 Disable reporting<br />

1 Enable reporting<br />

: integer type. Se<strong>ts</strong> the reporting interval of the battery capacity level.<br />

1...100 Amount that the remaining battery capacity must change before reporting).<br />

: integer type. Gives the remaining relative battery capacity level (in percentages).<br />

0 The battery is exhausted or ME does not have a battery connected<br />

1...100 remaining battery capacity level (in percentages). The provided values are dependant on the<br />

parameter . A value of 5 for parameter , means<br />

that the following values of are appliccable: 0, 5, 10, 15, … , 90, 95, 100.<br />

NOTE:<br />

100% capacity is always reported, even if is set to a value where no integer<br />

multiple equals 100.<br />

Implementation<br />

Optional.<br />

8.60 Battery connection status +CBCON<br />

Table 8.60-1: +CBCON parameter command syntax<br />

Command<br />

+CBCON=[]<br />

+CBCON<br />

+CBCON=<br />

Possible response(s)<br />

+CBCON: ,<br />

+CBCON: (list of supported s)<br />

Description<br />

Set command enables reporting upon change in battery connection status, with unsolicited result code<br />

+CBCON: .<br />

Read command returns the status of result code presentation and the current battery status.<br />

Test command returns values supported as compound values.<br />

Defined values<br />

: integer type. Enables and disables reporting of changes in the battery connection status.<br />

0 disable reporting<br />

ETSI