The schematic for the recording of the data generated by the TI-VPR is shown in Figure B-11. A<br />

video camera is positioned in front of the radar screen to record the images it displays. Video<br />

from this camera is sent to a date <strong>and</strong> time generator, <strong>and</strong> from there to one input of the video<br />

multiplexer (Colorado Video model 496-2C Video Signal Multiplexer (2 Channel). Video from<br />

the thermal imaging camera is sent to the second multiplexer input, <strong>and</strong> the video from the<br />

multiplexer is recorded directly to a DVD (high definition capacity 1 hr) using a Sony DVD<br />

recorder (model VRD-MC5). Figure B-12 shows a multiplexed image.<br />

Figure B-11. Diagram of data acquisition system for the thermal imaging camera <strong>and</strong> vertically<br />

pointing radar system.<br />