Installation<br />

Table 3–5. AC Microchron II Timer Relay Installation Procedure (Cont.)<br />

Step<br />

Procedure<br />

5 Attach the mating registration plate (packed with the AC Microchron II Timer<br />

Relay) to the plugboard and plug in the relay.<br />

6 Detach the cover that seals access to the thumbwheel switches by removing the<br />

tamper evident lead seal, two thumbnuts, and sliding the clear plastic cover off<br />

the studs.<br />

COVER<br />

1 2 3 4<br />

5<br />

THUMBWHEEL SWITCHES<br />

7 Adjust the thumbwheel switches to the desired timing interval.<br />

NOTE<br />

Certain switches contain “stops” and only rotate between<br />

allowable settings. For example, the “Tens of Minutes” switch can<br />

only rotate between the “0” and “1” positions and the “Tens of<br />

Seconds” switch can only rotate between the “0” and “5” positions.<br />

P1457, Rev. Nov/07 3–14 <strong>Alstom</strong> Signaling Inc.