Preventive Maintenance<br />

4.5.10. Power-Transfer Relay Test<br />

Follow the procedure in Table 4–16 to test a Power-Transfer Relay. See specific ED<br />

sheet for exact details.<br />

Table 4–16. Power-Transfer Relay Test Procedure<br />

Step<br />

Procedure<br />

1 Perform the visual inspection procedure in Table 4–2.<br />

2 Apply power to the relay.<br />

3 Use this circuit for testing power-transfer relays:<br />

110 V<br />

60 Hz<br />

12 V<br />

MAX.<br />

0-15 V<br />

AC<br />

V<br />

RELAY UNDER TEST<br />

3B<br />

3A<br />

3C<br />

3D<br />

RECTIFIER<br />

Drawing No. 59899-005-03<br />

4 See specific ED sheet for specifications.<br />

P1457, Rev. Nov/07 4–20 <strong>Alstom</strong> Signaling Inc.