Corrective Maintenance<br />

Table 6–13. Microchron II Timer Electronics Replacement Procedure (Cont.)<br />

Step<br />

Procedure<br />

8 Check for correct operation of the relay.<br />

NOTE<br />

If the relay completes its cycle (showing steady red LED during<br />

cycle) and then the green LED starts blinking but the relay does<br />

not pick, check the relay coil connections.<br />

9 Install the relay cover and seal the relay.<br />

P1457, Rev. Nov/07 6–28 <strong>Alstom</strong> Signaling Inc.