Installation<br />

3.4. INSTALLATION<br />

The B relay plugs into a plugboard assembly mounted on rack support bars. Plugboard<br />

assemblies:<br />

• are available in either B1 or B2 sizes<br />

• use insulators for separating the solder or crimp type terminals<br />

• hold the guide rods for alignment and securing the relay<br />

• hold the registration plates<br />

• can be provided with current or voltage test posts<br />

For a listing of plugboards, specialty parts, and mounting hardware refer to Section<br />

7.17., B Relay Plugboards and Terminal Boards.<br />

Most B relays are installed using the procedure provided in Table 3–2.<br />

Microchron II Timer Relay installation includes setting the timer. Follow the steps in<br />

Table 3–3 in the order provided to install a Microchron II Timer Relay (DC) or the steps<br />

in Table 3–5 to install an AC Microchron II Timer Relay.<br />

Built-in surge circuitry in the Microchron II Timer Relay provides adequate protection<br />

from transients on the power leads for circuits confined to a bungalow or train control<br />

relay room containing an installed Microchron II Timer Relay. If the energy circuit has<br />

contacts remote from the bungalow, follow the procedure in Table 3–4 to provide<br />

additional surge protection.<br />

NOTE<br />

To assure safe application of the AC Microchron II Timer Relay, all<br />

application circuits must be reviewed by <strong>Alstom</strong> engineering before it will<br />

be approved for use.<br />

P1457, Rev. Nov/07 3–2 <strong>Alstom</strong> Signaling Inc.