15.04.2015 Views

Type B Vital Relays - Alstom

Type B Vital Relays - Alstom

Type B Vital Relays - Alstom

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Corrective Maintenance<br />

6.4.3. Insulator Removal and Installation<br />

To remove and replace an insulator, follow the steps in Table 6–7 in the order provided.<br />

Table 6–7. Insulator Removal and Installation Procedure<br />

Step<br />

Procedure<br />

1 From the rear of the plugboard, squeeze the locking tab toward the insulator<br />

and push the insulator forward.<br />

LOCKING<br />

TAB<br />

SQUEEZE<br />

TOWARD<br />

INSULATOR<br />

2 Remove the insulator from the front of the plugboard.<br />

3 From the front of the plugboard, insert the new insulator end with the locking tab<br />

first. Push until the insulator is seated and the locking tab engages. The locking<br />

tab clicks when it engages.<br />

4 From the front of the plugboard, tug on the insulator to verify that the locking tab<br />

has engaged.<br />

P1457, Rev. Nov/07 6–10 <strong>Alstom</strong> Signaling Inc.