3.1. GENERAL<br />

This section contains general installation procedures for <strong>Type</strong> B relays. Included is a<br />

procedure for inspecting each relay prior to installation, followed by the installation and<br />

adjustment procedure.<br />

3.2. RELAY INSTALLATION TOOLS AND SUPPLIES<br />

See Appendix C for a summary of B relay tools. See Section 7 for a listing of installation<br />

plugboards and supplies.<br />

3.3. INSPECTION<br />

Upon receipt of a shipment of <strong>Type</strong> B relays, inspect them for cleanliness and overall<br />

condition. Also, always verify the operating characteristics of the relay before installing it<br />

in a particular circuit.<br />

Prior to installing a <strong>Type</strong> B relay, follow the inspection procedure provided in Table<br />

3–1. Refer to section 2, Figure 2–1 for an illustration identifying the basic B relay<br />

components.<br />

Table 3–1. B Relay Pre-Installation Inspection Procedure<br />

Step<br />

Procedure<br />

1 Check that the relay cover and seal are not damaged.<br />

WARNING<br />

BREAKING THE RELAY COVER SEAL VOIDS THE WARRANTY<br />

ON THE RELAY.<br />

2 Verify that the relay prong surfaces are clean and not bent.<br />

While the prongs of the relay that engage with the terminals in the plugboard are<br />

clean and adjusted when they leave the factory, there is always the chance that<br />

they may become dirty or bent in handling. If prongs are dirty, clean by<br />

burnishing.<br />

3 When relay racks complete with plugboards are received, verify they are clean<br />

and not broken or cracked. The terminals should lie close to the insulators. The<br />

guide rods should be straight and at right angles to the plugboard.<br />

P1457, Rev. Nov/07 3–1 <strong>Alstom</strong> Signaling Inc.