Preventive Maintenance<br />

4.5.6. Magnetic-Stick Relay Test<br />

To verify the performance of the magnetic-stick relay, follow the procedure in<br />

Table 4–12.<br />

Table 4–12. Magnetic-Stick Relay Test Procedure<br />

Step<br />

Procedure<br />

1 Perform the visual inspection procedure in Table 4–5.<br />

2 Stabilize relay by operating 5 to 10 times, alternately from NORMAL to<br />

REVERSE, at the saturation value specified on relays specific ED sheet.<br />

3 Saturate Reverse at value specified on ED sheet.<br />

4 Gradually reduce current to zero.<br />

5 Reverse polarity and gradually increase current to point where armature moves<br />

to normal contacts. Without further increase in current, armature must proceed<br />

through to full normal position against stop. This is the NORMAL PICKUP and<br />

WORKING current and must be within the limits specified on ED sheet.<br />

6 Saturate normal at value specified on ED sheet.<br />

7 Gradually reduce current to zero.<br />

8 Reverse polarity and gradually increase current to point where armature moves<br />

to Reverse contacts. Without further increase in current, armature must proceed<br />

through to full reverse position against stop. This is the REVERSE PICKUP and<br />

WORKING current and must be within the limits specified on the ED sheet.<br />

P1457, Rev. Nov/07 4–16 <strong>Alstom</strong> Signaling Inc.