Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Installation<br />
Table 3–5. AC Microchron II Timer Relay Installation Procedure<br />
Step<br />
Procedure<br />
1 Check that the relay cover and seal are not damaged.<br />
2 Verify that the relay prong surfaces are clean and not bent.<br />
While the prongs of the relay that engage with the terminals in the plugboards<br />
are clean and adjusted when they leave the factory, there is always the chance<br />
that they may become dirty or bent in handling.<br />
• If prongs are dirty, clean by burnishing.<br />
• If prongs are bent, bend them back into position so they make contact when<br />
the relay is installed.<br />
3 Review the operating characteristics of the relay and verify the appropriate relay<br />
is being installed before proceeding.<br />
Relay 50800-103-01 50800-104-01<br />
Input Voltage Range<br />
Input Power While Timing<br />
Input Power After Timing<br />
with Relay Energized<br />
88 to 135 Vrms, 60 Hz<br />
AC<br />
11 mA rms at 88 Vrms<br />
18 mA rms at 110 Vrms<br />
44 mA rms at 135 Vrms<br />
26 mA rms at 88 Vrms<br />
27 mA rms at 110 Vrms<br />
45 mA rms at 135 Vrms<br />
WARNING<br />
44 to 66 Vrms, 25 Hz AC<br />
23 mA rms at 44 Vrms<br />
54 mA rms at 55 Vrms<br />
161 mA rms at 66 Vrms<br />
52 mA rms at 44 Vrms<br />
61 mA rms at 55 Vrms<br />
148 mA rms at 66 Vrms<br />
THE AC MICROCHRON II TIMER RELAY MAY NOT BE<br />
INTERCHANGEABLE WITH A MOTOR-OPERATED TIMER IN<br />
EVERY CIRCUIT APPLICATION BECAUSE OF THE<br />
FOLLOWING DIFFERENCE BETWEEN THE TWO TIMERS:<br />
• AC MICROCHRON II TIMER RELAY - CHECK CIRCUIT<br />
OPENS AFTER TIME DELAY HAS EXPIRED, AND CLOSES<br />
WHEN POWER IS REMOVED<br />
• AC MOTOR TIMER - CHECK CIRCUIT OPENS AT<br />
BEGINNING OF TIME DELAY AND CLOSES WHEN POWER<br />
IS REMOVED<br />
4 For a new installation, check plugboard to ensure proper connections; refer to<br />
ED50800-103-01 for the 60 Hz relay or ED50800-104-01 for the 25 Hz relay.<br />
P1457, Rev. Nov/07 3–13 <strong>Alstom</strong> Signaling Inc.