15.04.2015 Views

Type B Vital Relays - Alstom

Type B Vital Relays - Alstom

Type B Vital Relays - Alstom

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Troubleshooting<br />

MICROCHRON II<br />

TIMER RELAY DOES<br />

NOT RELEASE<br />

NO<br />

IS RED LED<br />

ILLUMINATED?<br />

YES<br />

CHECK FOR VOLTAGE<br />

PRESENT AT RELAY<br />

TEST TERMINALS<br />

(SEE WIRING DIAGRAM)<br />

NO<br />

OK?<br />

YES<br />

REPLACE<br />

RELAY<br />

REFER TO BOOK OF<br />

PLANS FOR<br />

RELAY LOGIC<br />

CIRCUITRY<br />

Figure 5–6. Microchron II Timer Relay (AC or DC) Does Not Release<br />

NOTE<br />

Failure of a Microchron II Timer Relay to release with no voltage applied to<br />

the terminals could indicate a potential safety failure. Record the<br />

conditions and notify <strong>Alstom</strong> Signaling customer service as soon as<br />

possible.<br />

P1457, Rev. Nov/07 5–10 <strong>Alstom</strong> Signaling Inc.