Corrective Maintenance<br />

Table 6–10. Relay Structure Inspection Procedure (Cont.)<br />

Step<br />

Procedure<br />

8 Verify that each pusher does not rub against the contact springs or stop in any<br />

position. Adjust, if necessary.<br />

9 Verify that the armature does not bind, and rides properly on the armature<br />

bearing plate. Clearance between the front face of the armature and the edge of<br />

the armature retaining plate is .002 inches minimum and .004 inches maximum,<br />

for any position of the armature. Adjust, if necessary.<br />

10 Verify that the compression spring does not rub on stud in any position of the<br />

armature. Adjust, if necessary.<br />

11 Verify that the compression spring fits properly against shoulder on lock nut.<br />

Adjust, if necessary.<br />

12 Verify that the lock nut is properly in place on coil spring stud. Reseat and<br />

tighten, if necessary.<br />

P1457, Rev. Nov/07 6–16 <strong>Alstom</strong> Signaling Inc.