Theory of Operation<br />

A jumper on the AC Microchron II Timer Relay has replaced the motor back check<br />

contact that existed between contacts 53 and 63 in the AC Motor Timer. The new AC<br />

Microchron II Timer Relay inherently provides full “set” time from the instant energy is<br />

applied; therefore, no “motor” back check contact is required for this function.<br />

2.4.4.3.2. Replaceable AC Motor Timers<br />

With proper installation, the AC Microchron II Timer Relay can replace certain AC Motor<br />

Timers. Table 2–4 shows the AC Motor Timers it can replace.<br />

WARNING<br />

THE AC MICROCHRON II TIMER RELAY MAY NOT BE<br />

INTERCHANGEABLE WITH A MOTOR-OPERATED TIMER IN EVERY<br />

CIRCUIT APPLICATION BECAUSE OF THE FOLLOWING DIFFERENCE<br />

BETWEEN THE TWO TIMERS:<br />

• AC MICROCHRON II TIMER RELAY - CHECK CIRCUIT OPENS<br />

AFTER TIME DELAY HAS EXPIRED, AND CLOSES WHEN POWER<br />

IS REMOVED<br />

• AC MOTOR TIMER - CHECK CIRCUIT OPENS AT BEGINNING OF<br />

TIME DELAY AND CLOSES WHEN POWER IS REMOVED<br />

Table 2–4. Replaceable AC Motor Timers<br />

AC Microchron II Timer Relay Part Number<br />

50800-103-01 (60 HZ operation)<br />

50800-104-01 (25 Hz operation)<br />

AC Motor Timer Part Number<br />

56007-050-01<br />

56007-051-01<br />

56007-060-01<br />

56007-061-01<br />

56007-066-01<br />

56007-067-01<br />

56007-067-02<br />

56007-068-01<br />

56007-068-02<br />

56007-062-01<br />

56007-063-01<br />

56007-065-01<br />

56007-069-01<br />

56007-070-01<br />

P1457, Rev. Nov/07 2–28 <strong>Alstom</strong> Signaling Inc.