Corrective Maintenance<br />

6.5. MECHANICAL TEST PROCEDURES<br />

The mechanical test procedures are performed to ensure that the relay structure is<br />

properly adjusted. Table 6–10 provides the Relay Structure Inspection Procedure. Table<br />

6–11 provides the Mechanical Test and Adjustment Procedure.<br />

The mechanical test and adjustment procedures take place with the B relay cover<br />

removed. These procedures include verification of armature air gap, bridge travel and<br />

contact group measurements. Components identified as not meeting defined tolerances<br />

during the relay mechanical test are adjusted during the test procedure. Mechanical<br />

adjustments must be followed by electrical tests to verify relay performance.<br />

WARNING<br />

BREAKING THE RELAY COVER SEAL VOIDS THE WARRANTY ON<br />

THE RELAY.<br />