Preventive Maintenance<br />

4.3. PREVENTIVE MAINTENANCE TOOLS<br />

See Appendix C for a summary of B relay tools.<br />

A specific wrench is used to turn the terminal nut on the current test post to open the<br />

coil circuit. Figure 4–1 shows a Spanner Nut Wrench (also called the "E" post wrench,<br />

P/N 55393-003-01).<br />

Figure 4–1. Spanner Nut Wrench<br />

The Shop Test Rack, P/N 56573-002-01, is used to test relays in the shop. See<br />

Appendix C for details about the Shop Test Rack.<br />

Electrical tests for operating values on <strong>Type</strong> B2 two element vane relays are made with<br />

the Vane Relay Test Unit, P/N 20182-111-01. See Appendix C for details about this test<br />

unit.<br />

4.4. RELAY INSPECTION<br />

All <strong>Type</strong> B relays must be visually inspected prior to performing electrical tests. Each<br />

<strong>Type</strong> B relay is in a clear plastic case and the parts to be inspected can be seen with<br />

the cover installed and sealed.<br />

WARNING<br />

BREAKING THE RELAY COVER SEAL VOIDS THE WARRANTY ON<br />

THE RELAY.<br />

Visual inspection includes checking contacts for damage or misalignment, corrosion or<br />

other contamination of parts, loose parts inside cover, broken seal, cracked, broken or<br />

discolored covers and wear particles on inside of cover. The inspection procedure<br />

provided in Table 4–2 describes how to inspect a typical B1 relay. Table 4–3 describes<br />

how to inspect a vane relay. Table 4–4 is a general relay inspection procedure<br />

applicable to all other relays.<br />

NOTE<br />

If any damage is detected, the relay must be removed from service and<br />

replaced.<br />