Corrective Maintenance<br />

Table 6–2. B Relay Removal and Replacement Procedure (Cont.)<br />

Step<br />

Procedure<br />

4 Check that the replacement relay is correct by verifying that the part number on<br />

the nameplate of relay matches the number on the plugboard registration plate.<br />

Remove nametag from defective relay and install on replacement relay.<br />

REGISTRATION<br />

PLATE NUMBER<br />

NAME<br />

PLATE<br />

NAMETAG<br />

TEST DATA<br />

FORM<br />

5 To replace the B relay, grasp the relay by the top and bottom of the cover; slide<br />

it onto the guide rods.<br />

If adjacent relay prohibits grasping of relay on top and bottom, use the handle<br />

on the front to push the relay along the guides.<br />

P1457, Rev. Nov/07 6–3 <strong>Alstom</strong> Signaling Inc.