Corrective Maintenance<br />

Table 6–12. Microchron II Timer Electronics Removal Procedure<br />

Step<br />

Procedure<br />

1 Remove the relay cover and seal.<br />

2 Detach the white, four-position connector, P1 (located close to the relay base)<br />

from the Motherboard (DC version) or Timer board (AC version) by squeezing<br />

the side tabs while firmly pulling it away from the board.<br />

Front View of DC Relay<br />

P1<br />

P2<br />

VIEW SHOWN WITH SWITCH BOARD _<br />

AND BRACKET REMOVED<br />

Top View of AC Relay<br />

(J1)<br />

(P1)<br />

(P2)<br />

P1457, Rev. Nov/07 6–24 <strong>Alstom</strong> Signaling Inc.