Corrective Maintenance<br />

Table 6–11. Mechanical Test and Adjustment Procedure (Cont.)<br />

Step<br />

Procedure<br />

16 Insert a .010 inch feeler gauge under the armature stop screw to hold the back<br />

contacts open. Using a smaller bar under the bottom of the pusher, gently push<br />

up on the bar to see that the pusher rises slightly, without moving the armature.<br />

While holding the armature in this position, verify that the roller on each heel<br />

spring rests on the bottom of the jaw in the pusher.<br />

17 Adjust the springs, if necessary, so they always open the front contacts in case<br />

of a failure at the bottom end of the pusher.<br />

18 For Microchron II Timer <strong>Relays</strong>, follow the electronics replacement procedure<br />

provided in Table 6–13, and then continue with Step 19.<br />

For all other relays, place the cover on the relay. Verify that the gasket in the<br />

base groove is seated properly and then assemble the two gasket washers over<br />

the relay support tubes. Install and tighten the knurled nuts and apply the seal.<br />

19 Check the contact prong spacing on the back of the relay with the appropriate<br />

gauges: P/N 56260-008-01 and P/N 56260-010-01.<br />

20 Follow the electrical test procedure for the relay, provided in Section 4.<br />