Installation<br />

Table 3–2. B Relay Installation Procedure<br />

Step<br />

Procedure<br />

1 Verify the relay cover and seal are not damaged.<br />

2 Verify the surfaces of the relay prongs that engage with the terminals in the<br />

plugboards are clean and not bent.<br />

While the relay prongs are clean and adjusted when they leave the factory, they<br />

may become dirty or bent during storage and handling.<br />

• If prongs are dirty, clean by burnishing.<br />

• If prongs are bent, bend them back into position so the make contact when<br />

the relay is installed.<br />

3 Select the proper relay by checking the order reference number provided on the<br />

nameplate on the front of the relay. This number also appears on the detailed<br />

plans furnished with the installation and on the plugboard registration plate.<br />

REGISTRATION<br />

PLATE NUMBER<br />

NAME<br />

PLATE<br />

NAMETAG<br />

4 Slide the relay Nametag into slot.<br />

TEST DATA<br />

FORM<br />

P1457, Rev. Nov/07 3–3 <strong>Alstom</strong> Signaling Inc.