Preventive Maintenance<br />

4.5.1. AC Light-Out Relay Test<br />

The AC Light-Out Relay is available in two coil configurations:<br />

• A pair of low resistance coils wired in series<br />

• A low resistance coil and high resistance coil<br />

To obtain DROPAWAY, PICKUP, and WORKING current values follow the procedure in<br />

Table 4–7.<br />

Table 4–7. AC Light-Out Relay Test Procedure<br />

Step<br />

Procedure<br />

1 Perform the visual inspection procedure in Table 4–2.<br />

2 Saturate the relay coils with current at the value shown on the <strong>Relays</strong> ED sheet.<br />

Coils are connected in series unless otherwise indicated.<br />

3 Slowly decrease current and obtain DROPAWAY, which is the value at which<br />

the back contacts just make.<br />

4 Open circuit.<br />

5 Close circuit and slowly increase the current to obtain PICKUP, which is the<br />

value at which the front contacts just make.<br />

6 Continue to slowly increase the current to obtain WORKING current, which is<br />

the value at which the armature is against the front stop. Frequently the PICKUP<br />

and WORKING current values are the same.<br />

P1457, Rev. Nov/07 4–11 <strong>Alstom</strong> Signaling Inc.