Fate of Mercury in the Arctic 34<br />

sampling chain heated to 50 0 C, to sample air, Figure 2., page 33, and is described in detail as cited<br />

so the sampling system and method will therefore only be briefly reviewed.<br />

At the inlet, there is an elutriator and an impactor, with impactor plate. The elutriator is coated<br />

in cross linked teflon. The elutriator straightens the flow and accelerates it, by forcing it through an<br />

orifice onto a roughened impactor plate with no coating applied. The cut-off diameter is 2.5 µm, so<br />

only the fine fraction of particles flows past the active area of the denuder. The sample flow is 10<br />

litres per minute. The flow is controlled just prior to the denuder chain with a “dry cal” flow meter<br />

prior to and after sampling.<br />

Immediately following the impactor, there is a dead space prior to the annulus. This allows for<br />

expansion of air, from ambient to 50 o C, since KCl optimally collects RGM at this temperature<br />

(Landis et. al, 2002); as well as proper development of laminar flow, which is a necessary condition<br />

for proper functioning of denuders.<br />

9 annular denuders were available: 6 new, belonging to NERI and 3 approximately 1 year old,<br />

belonging to ORNL; however, there were only 4 complete sampling systems as depicted in Figure<br />

2., page 33.<br />

Measurements made in Barrow were therefore with US EPA denuders and sampling systems,<br />

to include the annular denuder system employed in the reactive gaseous mercury flux system.<br />

The denuders were characterized in the laboratory of Dr. Lindberg at Oak Ridge National lab<br />

prior to field deployment.<br />

Upon receipt, denuders were physically inspected. The physical inspection is an important<br />

aspect of quality control prior to using the denuders and includes checking for cracks, and ensuring<br />

that the threads produce a tight seal. Each new denuder was then numbered 1 – 6, by carefully<br />

etching with a diamond pen. The 3 older denuders were numbered X1 – X3.