Fate of Mercury in the Arctic 42<br />

vertical wind velocity, needed to calculate the REA flux, see later, and the value beta,<br />

also needed to calculate the vertical flux and the number of times each valve was<br />

switched in during the run. The data could only be retrieved by stopping the system, so<br />

data was seen only first after the sampling period. The text output file was not<br />

comparable with the file saved for each individual run, the .ACU extension files. In the<br />

text output file, the total number of counts did not add up to the total run time, and the<br />

value for the standard deviation of the vertical wind velocity and sometimes, beta, was<br />

different for the run than the value found in the .ACU file. Therefore, the .ACU values<br />

were used for consistency throughout analysis, since the counts in the .ACU file<br />

equalled the total run time. The data from the .ACU file for each run was imported by<br />

hand-typing into a spreadsheet where it was averaged for the entire sampling period and<br />

total sampling time for each denuder calculated by multiplying the switching time by the<br />

sampling frequency. The software allows adjustment of the sampling frequency and for<br />

the third channel, known as the MID channel to either remain open for constant, co-<br />

located sampling, or to open recording the air in the dead band, such that the sum of the<br />

three channels should equal concentrations contained from a separate constant sampling<br />

system, allowing some aspect of quality control, and employed for this study. The<br />

computer time was not internally changed for this study, but left at its original setting, 4<br />

hours ahead of Barrow, i.e., a run name with a start time noted as 20:00 was started at<br />

16:00 local time.<br />

4. A REA valve box, METSUPPORT model 1006-01, serial no. 10013, built to interface<br />

with the sampling front end with fast response valves, that are meant to run with 5 m<br />

long cables between the valve box and the switches, so that they might be mounted as<br />

close to the outgoing end of the denuder as possible. It was thought that heat from