<strong>SYNTEC</strong> <strong>CNC</strong> application <strong>manual</strong>1.3 termianl platform module operation instruction:RELAY 2 operation instruction:standards:size 140MM*170MMI/O points:12 RELAY OUTPUT + 40 INPUTCN1(mother)TO controllerCN2(public)To machineJP1JP2RLY0+RLY0-RLY1+RLY1-RLY2+RLY2-RLY3+RLY3-RLY4+RLY4-RLY5+RLY5-RLY6+RLY6-RLY7+RLY7-JP3RLY8+RLY8-RLY9+RLY9-RLY10+RLY10-RLY11+RLY11-RLY0RLY1RLY2RLY30RLY4RLY5RLY6RLY7RLY8RLY9RLY10RLY1197-<strong>CNC</strong>-RELAY2SN :FUSEGNDGNDIN0IN1IN2IN3IN4IN5IN6IN7IN8IN9IN10IN11IN12IN13IN14IN15JP7JP2JP3JP5GNDGND+5VGNDdescription:1. 12 RELAY contacts,contact standards:normal open,electic standards:1A ,220V2. each RELAY has a RED led to display, show relay action status,bright, for relayon3. 40 input contacts,build by Europe form terminal platform in 16 points input(I0..I15) , configure by screwdriver, receive open,short signal4. oher 24 points input(I16..I39) are put in CN2(public), build by 25 pin D type ,pin25GND other pin1..pin24 opposite (I16..I39),24 I point at all5. all I/O system need a +5V power supply(D68 green light display),this can sharewith encoder power in signal good situation6. CN1 is D type 25 pins(mother), connect to CN1(public) of PIO316